<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-27 19-35-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 56 dBuV YLEX
Pilot RDS Phase Difference
7.3 kHz 2.4 kHz 59 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 64 kHz 19038 1,9908
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,9 dBr 4,38 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 19:35, 27.06.2025
RT
"YleX Throwback: Womma Seppälä "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 64 kHz MIN: 11 kHz % above 76 kHz: 1,9908 Acquired: 2025/06/27 19.34.49 Total samples: 19038 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,3 dBr MIN: 1,9 dBr AVE: 4,38 dBr % above 12,2 dBr: 0,0 Last value: 4,3 dBr (2025/06/27 19.34.48) 19.20 19.22 19.24 19.26 19.28 19.30 19.32 19.34 0 2 4 6 Pm [dBr]